IBBIS v4.42.25: Fixes for Donor Testing, CUD, Product Sampling, Retro Registration, Billing, Bulk Orders, Record Storage, Conv to MNF, SDR and Phleb Performance

Scheduled Maintenance Report for LifeSouth IT

Completed

The scheduled maintenance has been completed.
Posted Feb 17, 2026 - 07:00 EST

In progress

Scheduled maintenance is currently in progress. We will provide updates as necessary.
Posted Feb 17, 2026 - 06:00 EST

Scheduled

Maintenance Details:

This release includes critical defect fixes to multiple IBBIS programs and services.

1. DT Reconciliation: Filter pool DINs
Pooled platelet DINs are excluded from Donor Testing Reconciliation, preventing unnecessary reconciliation records for pooled platelet testing.

2. CUD: query for received In Transit shipments needs evaluation
Ensures receipt timestamps are recorded correctly for inter-site transfers and prevents shipping workflows from proceeding without proper receipt validation.

3. EIS Token issue when logging out
Resolves a rare login token issue that could occur when users log out after extended idle periods.

4. EIS – holding enter button in password field results in multiple submissions
Prevents repeated login submissions caused by holding down the ENTER key on the login screen.

5. Product Sampling processing fails when platelet count is missing
Updates product sampling to re-enqueue processing when platelet count data is unavailable instead of failing the queue job.

6. Wording started to appear on top of other words in retro-registration
Fixes UI rendering issues where long site names caused overlapping text during retro-registration searches.

7. Improve Logging and Performance of pkg_billpost.price_all
Improves billing job performance, replaces console output with structured logging, and enforces log retention cleanup.

8. Investigate missing numbers on coversheet for pools to RION
Corrects missing pool and random counts on RION coversheets and updates spacing to avoid conflicts with shipping labels.

9. GNV – Issues with uploading a file to the equipment link for LSID 116200
Resolves file upload errors for equipment documentation by increasing the allowable upload size.

10. GNX – Converting to Manufacture Low Count Platelet, – ORA:01403 Error
Fixes an ORA:01403 “No Data Found” error when converting an APH platelet product with an added bag that lacks a tubing tare weight entry into a frozen manufacturing product.

11. IBBIS does not automatically UDT Testing Only donations when the SDR is scanned
Fixes a defect where Testing Only visits were not properly closed, ensuring Scan SDR automatically performs UDT processing without manual intervention.

12. Phleb Performance – Platelet charts aren't counting QNS
Corrects QNS calculations in platelet performance dashboards so Single, Double, Triple, and QNS values are accurately reflected in charts and percent-to-inventory calculations.

13. CASI – BP/Pulse fields improperly display yellow for acceptable measurements
Corrects CASI warning logic so yellow indicators display only when blood pressure or pulse values fall within defined warning ranges that require Medical Director awareness, preventing confusion for acceptable measurements.


MAINTENANCE IMPACT: The following services may be temporarily unavailable for the duration of this maintenance:
• EIS
• IBBIS
• Documentation Library

If you encounter issues relating to this maintenance, please report the problem to the Help Desk as described in procedure EMP.3.3 (Report a Computer or Network Issue). If this issue is critical, call the Help Desk at (352) 224-1685.
Posted Feb 13, 2026 - 10:17 EST
This scheduled maintenance affected: IBBIS, EIS, and CASI.